<< Previous Message Main Index Next Message >>
<< Previous Message in Thread This Month Next Message in Thread >>
Date   : Sat, 09 Sep 2006 08:58:43 +0100
From   : jgh@... (Jonathan Graham Harston)
Subject: Re: Bugs in ArmCoPro OS

>Message-ID: <4e624f8069info@...>
 
Also, the ARMCoPro OS doesn't pass A back on calls to OSGBPB. A
Tube Client OS should pass back A unchanged. OSGBPB returns A=&00
if call supported, or A=unchanged if call unsupported. [SJ MDFS
Manager's Guide, p10-2]
 
When writing HADFS I found so much documentation was actually
wrong in cruicial subtle details. Particularly error-prone is the
New Advanced User Guide and anything written by Watford
Electronics.
 
I tested every filing system I could detailing exactly what each
call /really/ did before implementing the calls correctly on
HADFS.
 

-- 
J.G.Harston - jgh@...                - mdfs.net/User/JGH
BBC IDE Hard Drive Interface - http://mdfs.net/Info/Comp/BBC/IDE